MikroTik Changelog Tracker
← Back to search All components

Component: health

85 changelog entries across 49 version(s)

Activity over time (changelog entries per month)

7.20.8 Long-term 2026-Jan-30 (4 days ago)
  • fixed fan and PSU state logging for MIPSBE devices;
7.21.1 Stable 2026-Jan-19 (2 weeks ago)
  • fixed fan and PSU state logging for MIPSBE devices;
7.21 Stable 2026-Jan-12 (3 weeks ago)
  • upgraded fan controller firmware to latest version;
7.19 Stable 2025-May-22 (8 months ago)
  • hide settings in CLI if there is nothing to show;
  • improved performance on devices with simple voltage sensors;
7.17 Stable 2025-Jan-16 (1 year ago)
  • added cpu-overtemp-check on ARM, ARM64 devices (CLI only);
  • changed PSU state from "no-ac" to "no-input";
  • hide settings in CLI if there is nothing to show;
  • removed board-temperature on RB5009UPr+S+IN device;
7.16 Stable 2024-Sep-20 (1 year ago)
  • fixed board-temperature for KNOT device (introduced in v7.15);
  • fixed bogus CPU temperature spikes for CCR2216 device;
  • fixed missing health for CRS112-8G-4S device (introduced in v7.15);
  • improved voltage measurements for RB912UAG-6HPnD and RB912UAG-5HPnD devices;
  • removed unnecessary health settings for RB921 and RB922 devices;
  • upgraded fan controller firmware to latest version;
7.15.1 Stable 2024-Jun-07 (1 year ago)
  • fixed board-temperature for KNOT device (introduced in v7.15);
  • fixed missing health for CRS112-8G-4S device (introduced in v7.15);
7.15 Stable 2024-May-29 (1 year ago)
  • added "cpu-temperature" for IPQ50xx devices;
  • added log for fan state changes on CRS3xx, CRS5xx, CCR2xxx, CCR1016r2, CCR1036r2 devices;
  • fixed fan behavior for CRS310-1G-5S-4S+ (introduced in v7.14);
  • fixed rogue voltage on CRS510-8XS-2XQ-IN;
7.14 Stable 2024-Feb-29 (1 year ago)
  • added limited manual control over fans for CCR1016r2, CCR1036r2 devices;
  • changed default "fan-min-speed-percent" from 0% to 12%;
  • improved fan control on CRS3xx and CCR1016-12S-1S+r2;
  • show voltage when powering KNOT R through Micro-USB;
  • updated health properties for CCR1016r2, CCR1036r2 devices;
7.13.3 Stable 2024-Jan-24 (2 years ago)
  • show voltage when powering KNOT R through Micro-USB;
7.13 Stable 2023-Dec-14 (2 years ago)
  • dynamically add and remove invalid sensors (e.g. sfp-temperature);
7.11 Stable 2023-Aug-15 (2 years ago)
  • added more gradual control over fans for CRS3xx, CRS5xx, CCR2xxx devices;
  • fixed configuration export for "/system/health/settings" menu;
7.9 Stable 2023-May-02 (2 years ago)
  • added limited manual control over fans for CRS3xx, CRS5xx, CCR2xxx devices;
  • fixed bogus value reporting for CRS510 device;
7.8 Stable 2023-Feb-24 (2 years ago)
  • fixed "temperature" and "power-consumption" readings for RB1100AHx4;
7.6 Stable 2022-Oct-17 (3 years ago)
  • fixed fan speed and temperature reporting on CCR1072;
  • improved voltage reading on RBmAP-2nD;
7.5 Stable 2022-Aug-30 (3 years ago)
  • fixed "temperature" and "power-consumption" readings on RB1100x4;
  • improved voltage reading on CRS112-8P-4S;
  • renamed "cpu-temperature" to "switch-temperature" on CRS312-4C+8XG, CRS326-24S+2Q+, CRS354-48P-4S+2Q+, CRS354-48G-4S+2Q+, CRS504-4XQ-IN, CRS518-16XS-2XQ;
7.4 Stable 2022-Jul-19 (3 years ago)
  • fixed requesting data from sensor when issuing "get" command;
  • fixed voltage reporting on some RBmAP-2nD devices;
6.49.1 Stable 2021-Nov-17 (4 years ago)
  • improved temperature reporting;
6.49 Stable 2021-Oct-06 (4 years ago)
  • added "phy-temperature" sensor monitoring for CRS312 device;
  • improved temperature readings on hEX S;
  • improved temperature reporting;
6.48.5 Long-term 2021-Sep-21 (4 years ago)
  • improved temperature reporting;
6.48.4 Stable 2021-Aug-18 (4 years ago)
  • fixed voltage monitor on BaseBox5 devices;
  • improved temperature reporting;
6.48.2 Stable 2021-Apr-09 (4 years ago)
  • fixed voltage monitor on BaseBox5 devices;
6.48 Stable 2020-Dec-22 (5 years ago)
  • changed PSU state parameter type to read-only;
  • removed unused "heater-control" and "heater-threshold" parameters;
6.47 Stable 2020-Jun-02 (5 years ago)
  • added "gauges" submenu with SNMP OID reporting;
  • improved stability for system health monitor on CCR2004-1G-12S+2XS;
6.45.9 Long-term 2020-Apr-30 (5 years ago)
  • fixed maximum SFP temperature reading under '/system health' menu;
6.46.4 Stable 2020-Feb-21 (5 years ago)
  • fixed maximum SFP temperature reading under '/system health' menu;
6.45.8 Long-term 2020-Jan-23 (6 years ago)
  • fixed health reporting on OmniTIK 5 PoE ac;
6.46.1 Stable 2019-Dec-13 (6 years ago)
  • fixed health reporting on OmniTIK 5 PoE ac;
6.44.6 Long-term 2019-Oct-24 (6 years ago)
  • improved fan control on CRS3xx and CCR1016-12S-1S+r2;
6.45.5 Stable 2019-Aug-26 (6 years ago)
  • improved fan control on CRS3xx and CCR1016-12S-1S+r2;
6.44 Stable 2019-Feb-25 (6 years ago)
  • improved fan control stability on CRS328-24P-4S+RM;
6.43.7 Stable 2018-Nov-30 (7 years ago)
  • fixed bad voltage readings on RB493G;
6.42.10 Long-term 2018-Nov-14 (7 years ago)
  • fixed bad voltage readings on RB493G;
6.42.9 Long-term 2018-Sep-27 (7 years ago)
  • added missing parameters from export;
  • fixed voltage measurements for RB493G devices;
6.43 Stable 2018-Sep-06 (7 years ago)
  • added missing parameters from export;
  • fixed voltage measurements for RB493G devices;
  • improved speed of health measurement readings;
6.42.4 Stable 2018-Jun-15 (7 years ago)
  • changed "PSU-Voltage" to "PSU-State" for CRS328-4C-20S-4S+;
  • fixed incorrect PSU index for CRS328-4C-20S-4S+;
6.40.8 Long-term 2018-Apr-23 (7 years ago)
  • fixed empty measurements on CRS328-24P-4S+RM;
6.42 Stable 2018-Apr-13 (7 years ago)
  • added log warning when switching between redundant power supplies;
  • fixed empty measurements on CRS328-24P-4S+RM;
6.41 Stable 2017-Dec-22 (8 years ago)
  • fixed bogus voltage readings on CCR1009;
6.38.1 Stable 2017-Jan-13 (9 years ago)
  • report fan speed for RB800 and RB1100 when 3-pin fan is being used;
6.37.4 Long-term 2017-Jan-13 (9 years ago)
  • report fan speed for RB800 and RB1100 when 3-pin fan is being used;
6.38 Stable 2016-Dec-30 (9 years ago)
  • show power consumption on devices which has voltage and current monitor;
6.37 Stable 2016-Sep-23 (9 years ago)
  • do not show psu and fan information for passive cooling devices;
6.36 Stable 2016-Jul-20 (9 years ago)
  • fixed broken factory voltage calibration data for some hAP ac boards;
  • fixed incorrect voltage after reboot on RB2011UAS;
6.35.4 Stable 2016-Jun-09 (9 years ago)
  • fixed broken factory voltage calibration data for some hAP ac boards;
  • fixed incorrect voltage after reboot on RB2011UAS;
6.35 Stable 2016-Apr-14 (9 years ago)
  • always report fan speed (even if it is 0);
  • swap fan2 and fan3 on CCR1072;
6.33 Stable 2015-Nov-06 (10 years ago)
  • fix voltage for CRS109, CRS112 and CRS210 if powered from external adapter;
6.32.2 Stable 2015-Sep-17 (10 years ago)
  • show correct voltage for CRS109,CRS112,CRS210 when powered through PSU and show voltage up to 27V when powered through PoE;
6.29 Stable 2015-May-27 (10 years ago)
  • fix voltage on some RB4xx;